Syncro-Link from FactoryOptic is a lens readout system.
This device sends Zoom, Focus and Iris as ranged values from 0-100% into a Camera object.
Add the FactoryOptic connection
The FactoryOptic IO can be added with a click on the (+) within the IO Connections.
Within the Inspector the FactoryOptic IO can be configurated.
The multicast ip should by default be: 237.37.37.37
The port should by default be: 37373
The interface needs to be the local used interface IP which is connected to the device.
To link the incoming FactoryOptic data to a camera object it’s necessary to add a map input.
The object ID needs to be matched with the sending device, is by default: 1