Search
Related topics are listed below.
Camera Analysis
Stage Precision » Stage Precision » Views / Elements » Objects » Utilities » Camera Analysis
The Camera Analysis object is a volume in the 3D space that can be used to analyze the coverage of multiple cameras. On top of the basic parameters like the position, scale and rotation, the Camera Analysis object has some unit parameters. Camera Analysis Setup …
Lens & Tracking Calibration Wizard
Stage Precision » Stage Precision » Workflows » Camera Calibration » Lens & Tracking Calibration Wizard
Interface A breakdown of the toolbar at the top of the Calibration Wizard: Switch to view the list of observations that have been captured Switch to the capture mode Open the list of calibration screens …
Lens Calibration
Stage Precision » Stage Precision » Workflows » Camera Calibration » Camera Calibration Workflows » Lens Calibration
The main objective of the Lens Calibration Tool is to generate a Lens Profile. Additional this tool can position/align screens within the correct 3D location/orientation. Prerequisites At least one calibration screen or by using a more complex wall, a multiscreen…
Tracking Alignment
Stage Precision » Stage Precision » Workflows » Camera Calibration » Camera Calibration Workflows » Tracking Alignment
The main objective of the Tracking Alignment Tool is to generate an Alignment Profile which captures the information about the relationship between the world coordinate from the tracking system to the world coordinate within SP. Prerequisites At least one…
Lens & Tracking Calibration
Stage Precision » Stage Precision » Workflows » Camera Calibration » Camera Calibration Workflows » Lens & Tracking Calibration
The main objective of the Lens & Tracking Calibration Tool is to generate a Lens Profile as well as an align the tracking system. Additional this tool can position/align screens within the correct 3D location/orientation. Prerequisites At least one calibration…
Image Calibration Wizard
Stage Precision » Stage Precision » Workflows » Camera Calibration » Image Calibration Wizard
Interface A breakdown of the toolbar at the top of the Image Calibration Wizard: Switch to expand the list of images captured for observation The button to capture an image from the camera feed for observation Run…
Genlock / Reference
Stage Precision » Stage Precision » Workflows » Project Framerate and Syncronisation » Genlock / Reference
Genlock Name Description Genlock Provider The specific genlock IO connection can be selected, using the target button. Interpolation Type Full interpolation None interpolation *The fps has four different color…
Media Input
Stage Precision » Stage Precision » Views / Elements » IO Connections » Synchronization » Media Input
Media Input handles different types of live inputs. These can be streams like NDI or multiple different SDI capture cards. SDI capture cards can also be used as Genlock Provider. !If you use Media Input as Genlock Provider please uncheck the option “Use as…
Simple Static Calibration
Stage Precision » Stage Precision » Workflows » Camera Calibration » Camera Calibration Workflows » Simple Static Calibration
The Static Calibration tool is to provide a quick and easy way to quickly align a static camera that does not move or do any pan/tilt/roll. At the end of this calibration, the camera would be placed relative to the calibration screen. *There will be NO lens profile…
Alignment with Marker
Stage Precision » Stage Precision » Workflows » Camera Calibration » Camera Calibration Workflows » Alignment with Marker
The main objective of the Alignment with Marker Tool is to align the tracking system using predefined markers in 3D space instead of patterns on a screen. Prerequisites Media Input into SP A camera object within SP A Lens Profile for the camera A supported…
Focusing on Points
Stage Precision » Stage Precision » Workflows » Camera Calibration » Camera Reposition Tools » Focusing on Points
The Focusing on Points Reposition Tool is used to update an existing Alignment Profile of a tracked camera. Typically this is used when the already aligned tracking system has been nudged / shifted slightly and only want to do a quick re-alignment. Prerequisites A…
Simple Static Calibration with Marker
Stage Precision » Stage Precision » Workflows » Camera Calibration » Camera Calibration Workflows » Simple Static Calibration with Marker
The Static Calibration tool is to provide a quick and easy way to quickly align a static camera that does not move or do any pan/tilt/roll. At the end of this calibration, the camera would be placed relative to predefined markers.. *There will be NO lens profile or…
Reposition from Screens
Stage Precision » Stage Precision » Workflows » Camera Calibration » Camera Reposition Tools » Reposition from Screens
The Reposition from Screen Tool is used to reposition a camera based on a known / pre-defined location of a screen. This tool can be used on a camera with a tracking system as well as static camera with no tracking system. Prerequisites At least one calibration…
Screens Alignment
Stage Precision » Stage Precision » Workflows » Camera Calibration » Camera Reposition Tools » Screens Alignment
The Screen Alignment Reposition Tool is used to reposition multiple screens based on a known calibrated tracked camera. *For this tool to work, the tracked camera needs at least Pan/Tilt encoders, but ideally a full 6DoF tracking system will generate better…
FAQ Camera Calibration
Stage Precision » Stage Precision » Workflows » Camera Calibration » FAQ Camera Calibration
How many observations should I do for my lens? It’s very difficult to say, there isn’t one way that works for all lenses. A high quality broadcast lens may only need a calibration point for zoom at every 20% step and then each at 0% and 100% focus. On the…
Optitrack Calibration
Stage Precision » Stage Precision » Views / Elements » Objects » Sensors » Optitrack Volume » Optitrack Calibration
The goal of the Optitrack Calibration is to calculate the relative positions of all the Optitrack Cameras in relationship to each other. There are different tools for calibrating multiple optitrack cameras through a wanding process to create one single Optitrack…
Optitrack Alignment
Stage Precision » Stage Precision » Views / Elements » Objects » Sensors » Optitrack Volume » Optitrack Alignment
Once all the cameras has been calibrated and their relative position between each other has been reconstructed, the next step is to offset / translate the entire group of cameras so the tracking volume is aligned with the 3D space within SP. There are several options…
Vbo (Vertex Buffer Object)
Stage Precision » Stage Precision » Views / Elements » IO Connections » Skeleton » Azure Kinect » Vbo (Vertex Buffer Object)
Coordinates Name Description Position The position of the kinect along the XYZ axis can be set. Scale The scale in meters can be set here. Rotation The rotation on the XYZ axis can be set. Vbo…
Perception Neuron
Stage Precision » Stage Precision » Views / Elements » IO Connections » Skeleton » Perception Neuron
Perception neuron is a motion capture suit with skeleton data. The IO connection takes in the perception neuron data. Perception Neuron Setup Name Description Server IP This is where the IP address of the server can be added. …
1.1.46
Stage Precision » Changelog » 1.1.46
New Integrations: Indiemark Lens Encoder Indiemark 2 Lens Encoder Glassmark II Lens Encoder Websocket New Nodes: Fading MTC In New Features: New Camera calibration tool: Simple Static Calibration to calibrate a fix lens and align the camera with a single…
Vicon
Stage Precision » Stage Precision » Views / Elements » IO Connections » 3D Tracking » Vicon
Vicon is a motion capture solution. www.vicon.com/ *This is only available for Virtual Production, Tracking, Light Tracking, and Full license. The Vicon IO can be added with a click on the (+) within the IO Connections. Stage Precision can be connected to…
Axis tools
Stage Precision » Stage Precision » Workflows » Camera Calibration » Axis tools
Axis is used to create a path of movement along an axis / track / spline based on encoder values and and image provider. If an object has multiple axes of movement, mutiple axes can be created one at a time and put one axis as a child of another to create a parent…
Lock Shield
Shield for Unreal » Setting & Functions (v0.8) » Shield Plugin Settings » Lock Shield
To “lock” Shield to a reference input, we recommend one of the following options: Fixed Framerate !This option should be used only, if the GPU is locked to an external house sync, like with an NVIDIA Quadro SYNC II card. Enable the option…
Camera Calibration
Stage Precision » Stage Precision » Workflows » Camera Calibration
SP has several methods of Camera Calibration Tools depending on the need. Calibration tools These tools can generate Lens Profiles and/or Alignment Profiles as well as position screens. Name Notes Generate Lens Profile Generate Alignment Profile…
Camera
Stage Precision » Stage Precision » Views / Elements » Objects » Tracked Objects » Camera
Camera Filter Distortion Viewer This places a standard camera in the 3D space. This camera can be set to a perspective or orthogonal view. Coordinates Name Description Position This will move the object along X, Y and Z axis in the…
Optitrack Camera
Stage Precision » Stage Precision » Views / Elements » Objects » Sensors » Optitrack Camera
Optitrack provides a wide range of camera sensors for tracking purposes. SP supports the Optitrack Prime and Slim cameras. *This is only available for Tracking, Light Tracking, Full, and Engineer license. Adding the Sensor To add a connection to an Optitrack camera,…
Azure Kinect
Stage Precision » Stage Precision » Views / Elements » IO Connections » Skeleton » Azure Kinect
To use the Azure Kinect IO connection, the kinect sensor(s) must first be added using the + button. !Azure Kinect SDK Version 1.4.1 (Firmware 1.6.110079014) is supported. Kinect Setup Coordinates Name Description Position The…
Image Based Blob Tracking
Stage Precision » Stage Precision » Workflows » Blob Tracking Workflows » Image Based Blob Tracking
Any sensor which provides an Image Provider can be used for Blob Tracking. This could be infrared cameras, depth cameras, head map cameras as well as RGB cameras. Device RGB Depth IR Filter Notes Azure Kinect …